Bitumen VG 40

No. Analysis Limit Test Method
1 Absolute Viscosity @60 ºC, Poises Min. 3200 IS 1206 (Part 2)
2 Kinematic Viscosity @135 ºC, cst Min. 400 IS 1206 (Part 3)
3 Flash Point (Cleveland Open Cup) ºC Min. 220 IS 1209
4 Solubility in Trichloroethylene, % Min. 99 IS 1206
5 Softening Point (R&B), ºC Min. 47 IS 1205
6 Penetration @25ºC, 0.1mm 100g, 5 Sec. 40-60 IS 1203
Tests on Residue from Thin Film Oven Tests / RTFOT
7 Viscosity Ratio @60ºC Max. 4.0 IS 1206 (Part 2)
8 Ductility @25̊ ºC, Cm, after thin film oven test Min. 25 IS 1208
9 Specific Gravity@27/27 ºC Min 0.99 IS 1202

 

* Conforms to (IS 73:2006) Specifications.

Usage: Bitumen VG-40 is used in highly stressed areas such as: Intersections, Air ports, truck parking lots, near toll booths and roads with heavy traffic loads in higher temperatures. Because of higher viscosity it also can be used instead of 30/40 bitumen penetration grade.